- EXHAUSTO.com
- Products
- Air handling units
Compact unit that can be put together to match the given requirements for process ventilation

VEX100 brings fresh, filtered air into the building and recovers heat from the extract air by means of its highly efficient heating heat exchanger. The incoming air can be heated and/or cooled using a complete range of heating/cooling coils.
VEX100 is suitable for tasks not covered by the Ecodesign Directive and where there is no need for such a high efficiency rating. For instance, for ventilating kitchens, bakeries, etc., where there is typically a surplus of heat but also a requirement for pre-heated supply air to the location.
x
| Variants | ECO efficiency level during optimal operating point | Efficiency level requirements | Max. Total efficiency (A-D) (%) | Overload protection |
|---|---|---|---|---|
| VEX140, horizontal version | 76,2N | 62N (2015) | 58,1 % | Built-in |
| VEX150, horizontal version | 74,4N | 62N (2015) | 60 % | Built-in |
| VEX160, horizontal version | 67,2N | 62N (2015) | 57,1 % | Built-in |
| VEX170H | 66,6N | 62N (2015) | 60,4 % | Built-in |
| VEX140, in vertical version | 76,2N | 62N (2015) | 58,1 % | Built-in |
| VEX150, vertical version | 74,4N | 62N (2015) | 60 % | Built-in |
| VEX160, vertical version | 67,2N | 62N (2015) | 57,1 % | Built-in |
| Variants | Connection direction | Type of exchanger | Conditions | Current overload protection | Motor class in accordance with IEC TS 60034-30-2 |
|---|---|---|---|---|---|
| VEX140, horizontal version | Horizontal | Crossflow | Conditions:> Density = 1.2 kg/m3> Pressure ratio < 1.11 > Other points in acc. with EC327/2011 (see product instructions) | Built-in | IE5 (Ultra Premium Efficiency) |
| VEX150, horizontal version | Horizontal | Crossflow | Conditions:> Density = 1.2 kg/m3> Pressure ratio < 1.11 > Other points in acc. with EC327/2011 (see product instructions) | Built-in | IE5 (Ultra Premium Efficiency) |
| VEX160, horizontal version | Horizontal | Crossflow | Conditions:> Density = 1.2 kg/m3> Pressure ratio < 1.11 > Other points in acc. with EC327/2011 (see product instructions) | Built-in | IE5 (Ultra Premium Efficiency) |
| VEX170H | Horizontal | Crossflow | Conditions:> Density = 1.2 kg/m3> Pressure ratio < 1.11 > Other points in acc. with EC327/2011 (see product instructions) | Built-in | IE5 (Ultra Premium Efficiency) |
| VEX140, in vertical version | Vertical | Crossflow | Conditions:> Density = 1.2 kg/m3> Pressure ratio < 1.11 > Other points in acc. with EC327/2011 (see product instructions) | Built-in | IE5 (Ultra Premium Efficiency) |
| VEX150, vertical version | Vertical | Crossflow | Conditions:> Density = 1.2 kg/m3> Pressure ratio < 1.11 > Other points in acc. with EC327/2011 (see product instructions) | Built-in | IE5 (Ultra Premium Efficiency) |
| VEX160, vertical version | Vertical | Crossflow | Conditions:> Density = 1.2 kg/m3> Pressure ratio < 1.11 > Other points in acc. with EC327/2011 (see product instructions) | Built-in | IE5 (Ultra Premium Efficiency) |
| Variants | Control signal with control system | Control signal with third party control system | Fluid temperature (air) | Regulation | Voltage input | Ambient temperature range |
|---|---|---|---|---|---|---|
| VEX140, horizontal version | Modbus | 0-10 V DC | -40°C...+40°C | Variable via motor control (MC) | 1 x 230 V | -30°C....+50°C |
| VEX150, horizontal version | Modbus | 0-10 V DC | -40°C....+40°C | Variable via motor control (MC) | 1 x 230 V | -30°C....+50°C |
| VEX160, horizontal version | Modbus | 0-10 V DC | -40°C....+40°C | Variable via motor control (MC) | 1 x 230 V | -30°C....+50°C |
| VEX170H | Modbus | 0-10 V DC | -40°C....+40°C | Variable via motor control (MC) | 3 x 400 V | -30°C....+50°C |
| VEX140, in vertical version | Modbus | 0-10 V DC | -40°C....+40°C | Variable via motor control (MC) | 1 x 230 V | -30°C....+50°C |
| VEX150, vertical version | Modbus | 0-10 V DC | -40°C....+40°C | Variable via motor control (MC) | 1 x 230 V | -30°C....+50°C |
| VEX160, vertical version | Modbus | 0-10 V DC | -40°C....+40°C | Variable via motor control (MC) | 1 x 230 V | -30°C....+50°C |
Dimensional drawings for VEX100H = horizontal version and VEX100V– vertical version respectively – both shown with round ducts.
| Variants | A (mm) | B (mm) | C (mm) | Ø connection (mm) | Weight (kg) | Weight for transport |
|---|---|---|---|---|---|---|
| VEX140, horizontal version | 1365 mm | 1145 mm | 750 mm | 315 mm | 190 kg | 105 kg (excl. doors, heat exchanger and fan sections) |
| VEX150, horizontal version | 1600 mm | 1295 mm | 835 mm | 400 mm | 278 kg | 164 kg (excl. doors, heat exchanger and fan sections) |
| VEX160, horizontal version | 1820 mm | 1495 mm | 940 mm | 500 mm | > med type A krydsveksler: 360 kg> med standard krydsveksler: 355 kg kg | 202 kg (excl. doors, heat exchanger and fan sections) |
| VEX170H | 2200 mm | 1895 mm | 1240 mm | > med type A krydsveksler: 665 kg> med standard krydsveksler: 626 kg kg | 411 kg (excl. doors, heat exchanger and fan sections) | |
| VEX140, in vertical version | 1145 mm | 1365 mm | 750 mm | 315 mm | 190 kg | 105 kg (excl. doors, heat exchanger and fan sections) |
| VEX150, vertical version | 1600 mm | 1295 mm | 835 mm | 400 mm | 278 kg | 164 kg (excl. doors, heat exchanger and fan sections) |
| VEX160, vertical version | 1820 mm | 1495 mm | 940 mm | 500 mm | > med type A krydsveksler: 360 kg> med standard krydsveksler: 355 kg kg | 202 kg (excl. doors, heat exchanger and fan sections) |
| Variants | Max. airflow (m³/h) | Minimum airflow |
|---|---|---|
| VEX140, horizontal version | 1780 m³/h | 250 |
| VEX150, horizontal version | 2980 m³/h | 500 |
| VEX160, horizontal version | 4860 m³/h | 600 |
| VEX170H | 7920 m³/h | 660 |
| VEX140, in vertical version | 1780 m³/h | 250 |
| VEX150, vertical version | 2980 m³/h | 500 |
| VEX160, vertical version | 4860 m³/h | 600 |
| Variants | Frequency (Hz) | Max. power of electrical coil 1 (kW) | Max. electrical output of unit (kW) | Voltage (V) | Max. power of electrical coil 2 | Maximum current - unit (A) | Maximum current - first coil (A) | Maximum current - second coil (A) | Max current of zero (A) |
|---|---|---|---|---|---|---|---|---|---|
| VEX140, horizontal version | 50 Hz | 7,2 kW | 1,6 kW | 1x230 V | 14,4 | 12,5 A | |||
| VEX150, horizontal version | 50 Hz | 12 kW | 2,7 kW | 3x400 V | 18 | 8,7 A | 26 A | 34,7 A | 15,0 A |
| VEX160, horizontal version | 50 Hz | 14,4 kW | 4,8 kW | 3x400 V | 21,6 | 15,5 A | 36,5 A | 46,7 A | 23,5 A |
| VEX170H | 50 Hz | 31,2 kW | 9,2 kW | 3x400 V | 46,8 | 17,5 A | 62,5 A | 85 A | |
| VEX140, in vertical version | 50 Hz | 7,2 kW | 1,6 kW | 1x230 V | 14,4 | 12,5 A | |||
| VEX150, vertical version | 50 Hz | 12 kW | 2,7 kW | 3x400 V | 18 | 8,7 A | 26 A | 34,7 A | 15,0 A |
| VEX160, vertical version | 50 Hz | 14,4 kW | 4,8 kW | 3x400 V | 21,6 | 15,5 A | 36,5 A | 46,7 A | 23,5 A |

MEKANISK YDEEVNE: In accordance with ds/en 1886 and certified by Eurovent
In accordance with ds/en 1886 and certified by Eurovent:
Strength of unit housing: D1 (M)
Tightness at negative pressure of -400 Pa: L1 (M)
Tightness at positive pressure of +700 Pa: L1 (M)
Filter bypass leakage: F9 at negative and positive pressure
Thermal transmittance: T2 (M)
Thermal bridging factor: TB3

The cabinets are made of Aluzinc AZ185 class C4 according to EN/ISO 12 944-2 and insulated with 50 mm mineral wool. This results in a low noise level to the surroundings/setup room.
The panel construction minimizes the formation of thermal bridges in the unit.

The motor sections are mounted in vibration dampers, which means less noise and vibration in the ducts, and there is no need to install flexible connections between the unit and the duct system.
The motor sections are retractable for easier service.
The motors are EC type with very high efficiency, meeting the requirements of the EcoDesign directive.

The aggregate is equipped with EXHAUSTO's EXstream impeller, one of the market's leading impellers in terms of low energy consumption and low noise level.

The easily accessible connection box with built-in supply isolator and circuit breakers ensures easy access for connection and adjustment.

The filter panels are easy to replace and can be ordered as filter class Coarse 85% (M5) or ePM1 55% (F7) according to ISO 16890.

VEX100-serien leveres med integreret eftervarmeflade, enten til vand eller el

VEX140 - VEX160:
Montagesokkel med fødder, der kan justeres i højden - 130 - 160 mm.
Montagesoklen er standard for VEX170.
With some projects, limited space means that internal transport of the air handling unit is difficult or impossible. This is why the VEX100 is available as a split version. It means that the air handling unit can be assembled and tested at the factory as normal – just without sealant. The air handling unit can therefore be easily taken apart at the installation site, transported as single sections, assembled, sealed and commissioned.
The table below shows the dimensions of the largest section (crossflow heat exchanger) and largest cabinet section, so that it can easily be determined whether there is sufficient space to allow internal transport.