THAV Roof terminal

THAV

Roof terminal

Roof terminal for vertical exhaust – used as end of the duct system above the roof. Attractive design, easy installation and low-noise design
THAV
THAV
EXHAUSTO roof terminal THAV is for air exhausts.

The roof terminals are for use where an architecturally attractive and technically sound roof termination is required for duct systems. The roof terminals are easy to mount on different roofing constructions.

The low-noise design makes them particularly suitable for built-up areas with high environmental requirements.

THAV's vertical air exhaust prevents polluted exhaust air from being deposited over surrounding areas or soiling the roof surface.
THAV

Product advantages

  • Modern design
  • Easy fitting
  • Low-noise design
  • 50 mm insulation (DS428-compliant)
  • Multiple sizes available
  • New
  • Refurbishment
  • Non-residential buildings
  • Mechanical extract ventilation systems
  • Etablissements scolaires
References Max. roof pitch
THAV160-600, roof terminal with vertical exhaust

30

THAV160-900, roof terminal with vertical exhaust

45

THAV160-1200, roof terminal with vertical exhaust

60

THAV200-600, roof hood with vertical exhaust

30

THAV200-900, roof terminal with vertical exhaust

45

THAV200-1200, roof hood with vertical exhaust

60

THAV250-600, roof terminal with vertical exhaust

30

THAV250-900, roof terminal with vertical exhaust

45

THAV250-1200, roof hood with vertical exhaust

60

THAV315-600, roof terminal with vertical exhaust

30

THAV315-900, roof terminal with vertical exhaust

45

THAV315-1200, roof terminal with vertical exhaust

60

THAV400-600, roof terminal with vertical exhaust

30

THAV400-900, roof terminal with vertical exhaust

45

THAV400-1200, roof terminal with vertical exhaust

60

THAV500-900, roof terminal with vertical exhaust

40

THAV500-1200, roof terminal with vertical exhaust

50

THAV630-900, roof terminal with vertical exhaust

35

THAV630-1200, roof terminal with vertical exhaust

45

Mått
THAV storlekC1 Ø (mm)C Ø (mm)L (mm)L1 (mm)Vikt (kg)Max. taklutning V
 160-600Ø160Ø2706007601630°
160-900Ø160Ø27090010601845°
160-1200Ø160Ø270120013602160°
200-600Ø200Ø3056007851230°
200-900Ø200Ø30590010851445°
200-1200Ø200Ø305120013851760°
250-600Ø250Ø3706008351430°
250-900Ø250Ø37090011351945°
250-1200Ø250Ø370120014352260°
315-600Ø315Ø4406009051930°
315-900Ø315Ø44090012052445°
315-1200Ø315Ø440120015052960°
400-600Ø400Ø51060010152530°
400-900Ø400Ø51090013153045°
400-1200Ø400Ø510120016153560°
500-900Ø500Ø61090014403540°
500-1200Ø500Ø610120017404250°
630-900Ø630Ø73890015505635°
THAV THAV
References C1 L (mm) L1 (mm) Ø C (mm) Empty weight (kg)
THAV160-600, roof terminal with vertical exhaust

160

600

760

270

16

THAV160-900, roof terminal with vertical exhaust

160

900

1060

270

18

THAV160-1200, roof terminal with vertical exhaust

160

1200

1360

270

21

THAV200-600, roof hood with vertical exhaust

200

600

785

305

12

THAV200-900, roof terminal with vertical exhaust

200

900

1085

305

14

THAV200-1200, roof hood with vertical exhaust

200

1200

1385

305

17

THAV250-600, roof terminal with vertical exhaust

250

600

835

370

14

THAV250-900, roof terminal with vertical exhaust

250

900

1135

370

19

THAV250-1200, roof hood with vertical exhaust

250

1200

1435

370

22

THAV315-600, roof terminal with vertical exhaust

315

600

905

440

19

THAV315-900, roof terminal with vertical exhaust

315

900

1205

440

24

THAV315-1200, roof terminal with vertical exhaust

315

1200

1505

440

29

THAV400-600, roof terminal with vertical exhaust

400

600

1015

510

25

THAV400-900, roof terminal with vertical exhaust

400

900

1315

510

30

THAV400-1200, roof terminal with vertical exhaust

400

1200

1615

510

35

THAV500-900, roof terminal with vertical exhaust

500

900

1440

610

35

THAV500-1200, roof terminal with vertical exhaust

500

1200

1740

610

42

THAV630-900, roof terminal with vertical exhaust

630

900

1550

738

56

THAV630-1200, roof terminal with vertical exhaust

630

1200

1850

738

61

THAV/THFVInsertion loss dB
size 125 Hz250 Hz500 Hz1000 Hz2000 Hz4000 Hz8000 Hz
160-60016222322125
160-90028232728178
160-12004112528332210
200-60035152524135
200-90056202930187
200-1200711263134239
250-6004713191274
250-90059202618106
250-1200611253023137
315-600451115944
315-9005815201255
315-120071020251576
400-60025911643
400-900261420965
400-12004714221177
500-900231217844
500-12002514211065
630-900141210753
630-1200151612863

THAV roof terminal is for vertical exhaust and has a built-in damper. A bird protection net is mounted at the top to prevent unwanted objects from entering the duct system.

Dimensions E, F and G apply only to PERFORM flashing.

With zinc, the flashing is always 100 mm

PERFORM flashing can cater for +/- 2.5° relative to the given roof pitch.

Products and accessories references

  • THAV160-600, roof terminal with vertical exhaust
    THAV160-600, roof terminal with vertical exhaust
  • THAV160-900, roof terminal with vertical exhaust
    THAV160-900, roof terminal with vertical exhaust
  • THAV160-1200, roof terminal with vertical exhaust
    THAV160-1200, roof terminal with vertical exhaust
  • THAV200-600, roof hood with vertical exhaust
    THAV200-600, roof hood with vertical exhaust
  • THAV200-900, roof terminal with vertical exhaust
    THAV200-900, roof terminal with vertical exhaust
  • THAV200-1200, roof hood with vertical exhaust
    THAV200-1200, roof hood with vertical exhaust
  • THAV250-600, roof terminal with vertical exhaust
    THAV250-600, roof terminal with vertical exhaust
  • THAV250-900, roof terminal with vertical exhaust
    THAV250-900, roof terminal with vertical exhaust
  • THAV250-1200, roof hood with vertical exhaust
    THAV250-1200, roof hood with vertical exhaust
  • THAV315-600, roof terminal with vertical exhaust
    THAV315-600, roof terminal with vertical exhaust
  • THAV315-900, roof terminal with vertical exhaust
    THAV315-900, roof terminal with vertical exhaust
  • THAV315-1200, roof terminal with vertical exhaust
    THAV315-1200, roof terminal with vertical exhaust
  • THAV400-600, roof terminal with vertical exhaust
    THAV400-600, roof terminal with vertical exhaust
  • THAV400-900, roof terminal with vertical exhaust
    THAV400-900, roof terminal with vertical exhaust
  • THAV400-1200, roof terminal with vertical exhaust
    THAV400-1200, roof terminal with vertical exhaust
  • THAV500-900, roof terminal with vertical exhaust
    THAV500-900, roof terminal with vertical exhaust
  • THAV500-1200, roof terminal with vertical exhaust
    THAV500-1200, roof terminal with vertical exhaust
  • THAV630-900, roof terminal with vertical exhaust
    THAV630-900, roof terminal with vertical exhaust
  • THAV630-1200, roof terminal with vertical exhaust
    THAV630-1200, roof terminal with vertical exhaust

Documents

Showing 1 - y of document
  • THAV/THFV Installation Instructions
    Manuals
    3 MB

1 software