THFV
Roof terminal
THFV
Roof terminal
Roof terminal for vertical air intake – used as end of the duct system above the roof. Attractive design, easy installation and low-noise design

THFV
EXHAUSTO roof terminal THFV is for outdoor air intakes.
The roof terminals are for use where an architecturally attractive and technically sound roof termination is required for duct systems. The roof terminals are easy to mount on different roofing constructions.
The low-noise design makes them particularly suitable for built-up areas with high environmental requirements.
The roof terminals are for use where an architecturally attractive and technically sound roof termination is required for duct systems. The roof terminals are easy to mount on different roofing constructions.
The low-noise design makes them particularly suitable for built-up areas with high environmental requirements.

Product advantages
- Modern design
- Easy fitting
- Low-noise design
- 50 mm insulation (DS428-compliant)
- Multiple sizes available
References | Max. roof pitch |
---|---|
THFV160-600, roof terminal for outdoor air intake | 30 |
THFV160-900, roof terminal for outdoor air intake | 45 |
THFV160-1200, roof terminal for outdoor air intake | 60 |
THFV200-600, roof terminal for outdoor air intake | 30 |
THFV200-900, roof terminal for outdoor air intake | 45 |
THFV200-1200, roof terminal for outdoor air intake | 60 |
THFV250-600, roof terminal for outdoor air inlet | 30 |
THFV250-900, roof terminal for outdoor air intake | 45 |
THFV250-1200, roof terminal for outdoor air intake | 60 |
THFV315-600, roof terminal for outdoor air inlet | 30 |
THFV315-900, roof terminal for outdoor air intake | 45 |
THFV315-1200, roof terminal for outdoor air inlet | 60 |
THFV400-600, roof terminal for outdoor air intake | 30 |
THFV400-900, roof terminal for outdoor air intake | 45 |
THFV400-1200, roof terminal for outdoor air intake | 60 |
THFV500-900, roof terminal for outdoor air intake | 40 |
THFV500-1200, roof terminal for outdoor air intake | 50 |
THFV630-900, roof terminal for outdoor air intake | 35 |
THFV630-1200, roof terminal for outdoor air intake | 45 |
Dimensions | ||||||
THFV size | C1 Ø mm | C Ø mm | L mm | L1 mm | Weight* kg | Max. roof pitch V |
160-600 | Ø160 | Ø270 | 600 | 760 | 16 | 30° |
160-900 | Ø160 | Ø270 | 900 | 1060 | 18 | 45° |
160-1200 | Ø160 | Ø270 | 1200 | 1360 | 21 | 60° |
200-600 | Ø200 | Ø305 | 600 | 785 | 12 | 30° |
200-900 | Ø200 | Ø305 | 900 | 1085 | 14 | 45° |
200-1200 | Ø200 | Ø305 | 1200 | 1385 | 17 | 60° |
250-600 | Ø250 | Ø370 | 600 | 835 | 14 | 30° |
250-900 | Ø250 | Ø370 | 900 | 1135 | 19 | 45° |
250-1200 | Ø250 | Ø370 | 1200 | 1435 | 22 | 60° |
315-600 | Ø315 | Ø440 | 600 | 905 | 19 | 30° |
315-900 | Ø315 | Ø440 | 900 | 1205 | 24 | 45° |
315-1200 | Ø315 | Ø440 | 1200 | 1505 | 29 | 60° |
400-600 | Ø400 | Ø510 | 600 | 1015 | 25 | 30° |
400-900 | Ø400 | Ø510 | 900 | 1315 | 30 | 45° |
400-1200 | Ø400 | Ø510 | 1200 | 1615 | 35 | 60° |
500-900 | Ø500 | Ø610 | 900 | 1440 | 35 | 40° |
500-1200 | Ø500 | Ø610 | 1200 | 1740 | 42 | 50° |
630-900 | Ø630 | Ø738 | 900 | 1550 | 56 | 35° |

References | C1 | L (mm) | L1 (mm) | Ø C (mm) | Empty weight (kg) |
---|---|---|---|---|---|
THFV160-600, roof terminal for outdoor air intake | 160 |
600 |
760 |
270 |
16 |
THFV160-900, roof terminal for outdoor air intake | 160 |
900 |
1060 |
270 |
18 |
THFV160-1200, roof terminal for outdoor air intake | 160 |
1200 |
1360 |
270 |
21 |
THFV200-600, roof terminal for outdoor air intake | 200 |
600 |
785 |
305 |
12 |
THFV200-900, roof terminal for outdoor air intake | 200 |
900 |
1085 |
305 |
14 |
THFV200-1200, roof terminal for outdoor air intake | 200 |
1200 |
1385 |
305 |
17 |
THFV250-600, roof terminal for outdoor air inlet | 250 |
600 |
835 |
370 |
14 |
THFV250-900, roof terminal for outdoor air intake | 250 |
900 |
1135 |
370 |
19 |
THFV250-1200, roof terminal for outdoor air intake | 250 |
1200 |
1435 |
370 |
22 |
THFV315-600, roof terminal for outdoor air inlet | 315 |
600 |
905 |
440 |
19 |
THFV315-900, roof terminal for outdoor air intake | 315 |
900 |
1205 |
440 |
24 |
THFV315-1200, roof terminal for outdoor air inlet | 315 |
1200 |
1505 |
440 |
29 |
THFV400-600, roof terminal for outdoor air intake | 400 |
600 |
1015 |
510 |
25 |
THFV400-900, roof terminal for outdoor air intake | 400 |
900 |
1315 |
510 |
30 |
THFV400-1200, roof terminal for outdoor air intake | 400 |
1200 |
1615 |
510 |
35 |
THFV500-900, roof terminal for outdoor air intake | 500 |
900 |
1440 |
610 |
35 |
THFV500-1200, roof terminal for outdoor air intake | 500 |
1200 |
1740 |
610 |
42 |
THFV630-900, roof terminal for outdoor air intake | 630 |
900 |
1550 |
738 |
56 |
THFV630-1200, roof terminal for outdoor air intake | 630 |
1200 |
1850 |
738 |
61 |
THFV | Insertion loss dB | ||||||
size | 125 Hz | 250 Hz | 500 Hz | 1000 Hz | 2000 Hz | 4000 Hz | 8000 Hz |
160-600 | 1 | 6 | 22 | 23 | 22 | 12 | 5 |
160-900 | 2 | 8 | 23 | 27 | 28 | 17 | 8 |
160-1200 | 4 | 11 | 25 | 28 | 33 | 22 | 10 |
200-600 | 3 | 5 | 15 | 25 | 24 | 13 | 5 |
200-900 | 5 | 6 | 20 | 29 | 30 | 18 | 7 |
200-1200 | 7 | 11 | 26 | 31 | 34 | 23 | 9 |
250-600 | 4 | 7 | 13 | 19 | 12 | 7 | 4 |
250-900 | 5 | 9 | 20 | 26 | 18 | 10 | 6 |
250-1200 | 6 | 11 | 25 | 30 | 23 | 13 | 7 |
315-600 | 4 | 5 | 11 | 15 | 9 | 4 | 4 |
315-900 | 5 | 8 | 15 | 20 | 12 | 5 | 5 |
315-1200 | 7 | 10 | 20 | 25 | 15 | 7 | 6 |
400-600 | 2 | 5 | 9 | 11 | 6 | 4 | 3 |
400-900 | 2 | 6 | 14 | 20 | 9 | 6 | 5 |
400-1200 | 4 | 7 | 14 | 22 | 11 | 7 | 7 |
500-900 | 2 | 3 | 12 | 17 | 8 | 4 | 4 |
500-1200 | 2 | 5 | 14 | 21 | 10 | 6 | 5 |
630-900 | 1 | 4 | 12 | 10 | 7 | 5 | 3 |
630-1200 | 1 | 5 | 16 | 12 | 8 | 6 | 3 |